PLEASE CLICK TO VIEW TABLE IN METRIC UNIT SYSTEM

Specifications

 

Horizontal (VPT)

 

Unit

4016/24

4025/24

4035/36

4050/48

Uniform Zone Size (HxWxL)

in

12 x 12 x 24

16 x 24 x 24

24 x 24 x 36

32 x 36 x 48

Hearth Capacity

lb

175

800

1350

2650

Furnace Size (HxWxL)

ft

8 x 10 x 11.5

8.5 x 10 x 13

10 x 11.5 x 6.5

11.5 x 16.5 x 26

Furnace Volume

ft3

1.2

3

5.5

7.5

Furnace Weight

tons

4.5

7

10

13.5

Operating Temperature Range

°F

300 – 2400

Convection Heating Range

°F

300 – 1550

Temperature Uniformity

°F

+/- 10

Heating Element Power

kW

45

90

150

240

Maximum Cooling Pressure

bar

6 or 10

Blower Motor Power 6/10 bar

hp

40/50

75/125

125/150

150/200

Maximum Convection Heating Pressure

bar

3

Convection Heating Fan

Motor Power

kW

-

2.0

2.0

5.5

Operating Vacuum Level

m

10

Leak Up Rate

 

<1 x 10-3 mbar x l/s

Cooling Water Consumption

During Heating Cycle

During Quench Cycle [6bar]

[10bar]

 

gpm

6

15

25

45

gpm

35

65

130

220

gpm

40

90

175

260

Cooling Gas (N2) [6bar]

[10bar]

scf

250

640

960

1590

scf

425

1060

1600

7650